Celbar Spray on Systens
(713) 433-6701 or Toll Free: 800-444-1252
info@celbar.com

Why Celbar?


Celbar Cellulose InsulationWith present day emphasis on energy conservation, noise control and structure protection, the use of Celbar is rapidly expanding in apartments, townhouses, single family detached homes, hotels/motels, offices, hospitals and other types of construction. State, local and sometimes federal laws governing sound transmissions though walls and ceilings, as well as minimum energy efficiency standards are being passed and enforced. To meet these stringent requirements - Celbar is the answer.

Celbar is an insulation product and therefor will naturlaly help control ever increasing utility costs. Celbar is also abelt o substantially reduce sound transmission because of the elasticity and density of the cellulose fibers. Compared to the common method of stapling insulation between studs or rafters, Celbar's monolithic coating is sprayed-on, for a better sounds and thermal control barrier.

Fire Rated Assemblies - Celbar has been tested in a full scale assembly per ASTM-E-119 and can be used in hourly rated partitions.Houston, BMC Campus, Celbar

In today's fast pace construction schedules, sound and conditioned air are commonly transferred through holes and cracks created by the various trades involved. Additionally, job site construction often permits other holes or cracks to form, either by material damage or labor errors. With Celbar, these problem areas can be corrected, as well as solving nouse from plumbing or other high use areas.

By using Celbar and the spray method of application, you can now offer better sound control by drastically reducing noise transmission. Facility cost of operation is controlled because of Celbar's unique thermal insulation properties. High density, low flame spread rating and other product qualities make Celbar an excellent method for facility protection.

Four Seasons Maui using CelbarCelbar offers the modern means of controlling energy costs, noise transmissions and facility protection, while adding ease of application at compettitive prices.

A partial list of satisfied hotels which have used Celbar in partition walls includes Circus Circus, Guest Quarters, Hilton, Holiday Inn, Hyatt, Marriott, Ramada, Residence Inns, Sheraton, and Warwick.



21/2" Metal Studs With 1/2" Gypsum Wallboard - both sides.

TEST RESULT
A. No Sound Control material used 31 STC
B. 21/2" sound barrier batt 33 STC
C. 21/2" sound barrier batt and 1/2" cellutex board 37 STC
D. 11/2" Celbar Spray 49 STC


Celbar is Fire Resistant

FIRE HAZARD CLASSIFICATION

Underwriters Laboratories; Reference #R-5499.
• ICBO-Approval Number 2262
• Southern Building Code-Approval Number 9566
• HUD-FHA-VA-Permits the use of in projects
they finance-based on ’s compliance with UMB-80


METAL STUD CONSTRUCTION

55 2 5/8" metal studs, 2 layers 5/8" gypsum board
on one side, 1 layer 5/8" gypsum board on the
opposite side: 2 1/2"
53 3" metal studs, 1 layer 5/8" gypsum board on
each side: 2"
51 21/2" metal stud 24" O.C. faced both sides with
5/8" gypsum wallboard: 11/2"

WOOD STUD ASSEMBLIES

51 2"x4" wood studs, 1 layer 5/8" gypsum board
on each side: 31/2"
50 2"x4" wood studs, 1 layer 5/8" gypsum board
on each side: 2"
ISO 9001:2008
ISO 9001:2008

Underwriters Laboratory
Underwriters Laboratory
Since 1966

recycle Earth

energy

12315 Robin Blvd. | Houston, Texas 77045, USA | (713) 433-6701 or Toll Free: 800-444-1252 | info@celbar.com