Many competitors argue that because cellulose insulation is made from paper, it’s naturally more flammable than other forms of insulation. They neglect to say that cellulose insulation is treated with fire retardants, giving cellulose wall assembly an effective 1-hour fire rating.

Cellulose also meets all Federal regulations and ASTM standards for fire safety, in accordance with UL 723 and ASTM C-739-05b characteristics.

Fire Spread and Smoke Developed are two key metrics regarding how insulation will perform in a fire.

Fire Spread refers to the speed at which flames spread along the surface of the insulating material. Smoke Developed refers to the amount of smoke that is produced while the product burns. In most house fires, it’s not the flames that cause injury or death, but rather smoke inhalation. Smoke also creates confusion and can obscure fire exits.

In one study, the ratings show that cellulose insulation outperforms the competition on these two key metrics. On smoke developed, les than 400 is a passing score. In order to pass, Open Cell Foam needs an additional component to meet the requirements.

Insulation Type
Flame Spread
Smoke Developed
Celbar Insulation 15 0
Fiberglass 0-5 <50
Open Cell Foam 25 <450

 

NFPA 286 describes a method for determining the contribution of interior finish materials to room fire growth during specified fire explosure condition. The following test used insulation as the interior finish material, and should not be considered indicative of results when another interior finish material, such as gypsum wall board, is covering the insulation. This method is not intended to evaluate the fire endurance of wall or ceiling assemblies, nor is it able to evaluate the effect of fires originating within the assembly.

NFPA 286 Insulation Comparison Testing: Cellulose Insulation Manufacturers Association November 2007 - January 2008

Standard Methods of fire testing for evaluating contrubution of wall and ceiling interior finish to room fire growth

Cellulose
Open Cell Foam

Go to
www.celbar.com 
for more info


12315 ROBIN BLVD.
HOUSTON, TX 77045
Office: (800) 444-1252
Fax: (713) 433-2029
Email: kbradshaw@celbar.com
www.celbar.com

 

ISO 9001:2008
ISO 9001:2008

Underwriters Laboratory
Underwriters Laboratory
Since 1966

recycle Earth

energy

12315 Robin Blvd. | Houston, Texas 77045, USA | (713) 433-6701 or Toll Free: 800-444-1252 | info@celbar.com